Calculation of parameters of technological equipment used in the hydrodynamic method of cleaning the drainage
Abstract
Calculations are presented to determine the pressure loss in the water supply elements of the installation for washing the drainage, taking into account the used water flow rate, the inner diameter of the washing pipe and its length. Based on the calculations, it is recommended that the installation for washing the drainage UPD-120 be completed with a flushing pipe with an inner diameter of
20 mm and a length of 300 m.
About the Authors
N. N. PogodinBelarus
A. S. Anzhenkov
Belarus
V. A. Bolbyshko
Belarus
References
1. Чугаев, Р. Р. Гидравлика / Р. Р. Чугаев. – Л. : Энергия, 1971. ‒ 552 с.
2. Примеры расчета по гидравлике / А. Д. Альтшуль [и др.]. – М. : Стройиздат, 1977. – 255 с.
3. Павловский Н. Н. Краткий гидравлический справочник / Н. Н. Павловский ; под ред. Р. Р. Чугаева. – Л. ‒ М. : Госиздат , 1940. – 314 с.
Review
For citations:
Pogodin N.N., Anzhenkov A.S., Bolbyshko V.A. Calculation of parameters of technological equipment used in the hydrodynamic method of cleaning the drainage. Land Reclamation. 2020;(2):5-11. (In Russ.)