Preview

Land Reclamation

Advanced search

BORE FOR DEEP SUPPRESSIONS OF PEAT FIRES

Abstract

With a purpose of peat fires localization and liquidation efficiency increase the bore of deep suppression is developed, which provides the water (fire suppressing composition) direct delivery into a ground to the depth up to 1m.The design of a bore for the fires deep suppression on peat swamps without use of water external sources is presented, and the tests results are presented in the article, too. Mounting the tank on the water source or use the several bores simultaneously will essentially increase the efficiency of peat fires localization and liquidation in depth up to 1 m.

About the Authors

E. V. Stashevsky
Научно-практический центр Гродненского областного управления МЧС Республики Беларусь
Belarus


S. B. Shatunov
Scientific Practical Centre of Grodno Regional Department of Emergency Ministry of Belarus
Belarus


References

1. Баратов А.Н., Корольченко А.Я., Кравчук Г.Н. и др. Пожароопасность веществ и материалов и средств их тушения. - М.: Химия ,1990

2. Еношевский Б.А., Еношевский В.Б. Охрана труда и противопожарная защита в торфяной промышленности. - Мн.: Высшая школа, 1983


Review

For citations:


Stashevsky E.V., Shatunov S.B. BORE FOR DEEP SUPPRESSIONS OF PEAT FIRES. Land Reclamation. 2006;(2):166-168. (In Russ.)